pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.






Filtered Search Results

OHAUS™ Starter pH Pen Meters
Convenient pH testing. OHAUS Starter pH Pen Meters offer a convenient way to measure pH, or the relative acidity or alkalinity of a sample at a given temperature. The pH pen meters can be completely operated with just one hand, freeing up your other hand to handle samples.

Calibration Points | 3 |
---|---|
Includes | 4 1.5V Batteries |
Type | Portable pH Meter |
Log Function Type | Automatic Data Logging |
Data Points | 30 |
Backlight Option | None |
Weight (English) | 0.24 lb. |
Range (pH) | 0 to 14 |
Calibration | Automatic/Manual |
For Use With (Application) | Measuring pH, or the relative acidity or alkalinity of a sample at a given temperature |
Battery Type | 4 x AG13 1.5 V Micro Alkaline |
Accuracy (pH) | ±0.1 |
Weight (Metric) | 110 g |
Thermo Scientific™ Orion™ Epoxy Bodied Temperature Probes
Get fast, accurate measurements in lab or field with this ATC Probe, which automatically corrects pH measurements for variation in electrode slope.

Diameter (English) Body | 0.2 in. |
---|---|
Type | ATC Probe |
Accuracy | ±1°C |
Length (Metric) | 120 mm |
Temperature (English) Operating | 32°F to 176°F |
pH Range | 0 to 14 |
Length (English) | 4.7 in. |
Material | Epoxy |
Diameter (Metric) Body | 6 mm |
Temperature (Metric) Operating | 0°C to 80°C |
Thermo Scientific™ Orion™ Temperature Probes
Automatically correct pH measurements for variation in electrode slope due to temperature change.

Temperature (English) Operating | 32°F to 212°F |
---|---|
Storage Requirements | Store in air |
Temperature (Metric) Operating | 0°C to 100°C |
Thermo Scientific™ Orion™ Dissolved Oxygen/BOD Probe
Make any pH meter a dissolved oxygen meter with this dissolved oxygen/BOD probe.

Dissolved Oxygen (Concentration Range) | 0 to 14 ppm |
---|---|
For Use With (Equipment) | Dissolved Oxygen/BOD Probe |
Sensor Types | Polarographic Dissolved Oxygen Sensor |
Temperature (Metric) Operating | 15°C to 35°C |
METTLER TOLEDO™ InLab™ Routine pH Electrodes

A combination pH electrode with an integrated temperature sensor and chemically resistant HA glass body. It is designed for general lab applications and ideal for use at high pH values (IP67 rated).

Type | Combination Electrode |
---|---|
Temperature (Metric) Range | 0°C to 100°C |
pH Range | 0 to 14 |
Membrane | HA Glass |
Material | Glass |
Junction | Ceramic |
Temperature (Metric) Operating | 0°C to 100°C |
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.

Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
---|---|
Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
Memory | Non-volatile |
Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Resolution (pH) | 0.1, 0.01 or 0.001 pH |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
Display Type | 7-in. High-resolution Color Graphic LCD |
Resolution (mV) | 0.1 mV |
Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
Data Points | 10,000 with Date and Time Stamp |
Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Warranty | 2 year meter warranty |
Temperature Accuracy | ±0.3°C, ±0.5°F |
Calibration Points (ISE) | Up to 5 |
Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Accuracy (TDS) | ±0.5% reading |
Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
Keypad | Capacitive touchscreen user interface |
Outputs | USB flash drive, computer or printer (STARA-106) |
Temperature Range (English) | -22.0°F to +266.0°F |
Range (Relative mV) | -2000 to 2000 mV |
Calibration Points (pH) | 1 to 5 points |
Backlight Option | Yes |
Range (mV) | -2000 to 2000 mV |
Range (ORP) | -2000 to 2000 mV |
Methods | 10 per channel (20 total) |
Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
Range (pH) | -2 to 20 |
TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
Channels | 2 |
Accuracy (pH) | ±0.002 pH |
Range (ISE) | 0.0001 to 19999 |
Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
Accuracy (Salinity) | ±0.5% reading |
Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
Accuracy (Conductivity) | ±0.5% reading |
Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
Weight (Metric) | 1.00 kg |
Resolution (ORP) | 0.1 mV |
Calibration Points (Conductivity) | 1 to 5 points |
Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
Isopotential Point | 7.000 pH; 1.000 ion concentration |
Accuracy (Resistivity) | ±0.5% reading |
AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
IP Rating | IP54 |
Weight (English) | 2.20 lbs. |
Range (Ion) | 0.0001 to 19999 |
Temperature Range (Metric) | -30.0°C to +130.0°C |
Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Pro Star PH211 pH/ORP Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PH211 bench meter is well suited for laboratories that desire a modern meter with advance performance.

Memory | Non-volatile |
---|---|
Resolution (pH) | 0.1, 0.01 or 0.001 pH |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature |
Range (pH) | -2 to 20 |
Channels | 1 |
Accuracy (pH) | ±0.002 pH |
Display Type | 7-in. High-resolution Color Graphic LCD |
Resolution (mV) | 0.1 mV |
Data Points | 10,000 with Date and Time Stamp |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
Inputs | BNC for pH or ORP, 8-pin MiniDIN for ATC, pin-tip for reference |
Accuracy (Temperature) | ±0.3°C, ±0.5°F |
Weight (Metric) | 1.00 kg |
Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Warranty | 2 year meter warranty |
Isopotential Point | 7.000 pH |
AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Calibration | pH, ORP, Temperature |
Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 2 (Temperature) |
Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
IP Rating | IP54 |
Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
Keypad | Capacitive touchscreen user interface |
Model | PH211 |
Outputs | USB flash drive, computer or printer (STARA-106) |
Range (Relative mV) | -2000 to 2000 mV |
Backlight Option | Yes |
Temperature Range (English) | -22°F to +266°F |
Calibration Points (pH) | 1 to 5 points |
Weight (English) | 2.20 lbs. |
Resolution (Temperature) | 0.1°C, 0.1°F |
Temperature Range (Metric) | -30°C to +130°C |
Range (mV) | -2000 to 2000 mV |
Methods | 10 |
Range (ORP) | -2000 to 2000 mV |
Fisherbrand™ accumet™ Basic AB330 Benchtop Laboratory Conductivity Meter
Ideal for daily conductivity, TDS and salinity testing of your routine laboratory samples, the accumet™ Basic AB330 Benchtop Meter provides essential functions needed without complicated functions at a budget-friendly price.
Memory | Non-volatile |
---|---|
Cell Constant | 0.1 to 10 |
Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature |
Temperature (Metric) Reference | 15, 20, 25 or 30°C |
Temperature Coefficient | 0 to 10 %/°C |
TDS Factor Range | 0.4 to 1 |
Range (Salinity) | 0 to 80 ppt |
Data Management Details | Printed or CSV Format |
Temperature Compensation | Linear |
Display Type | 5 in. LCD |
Accuracy (Salinity) | ±1% Full Scale |
Resolution (Salinity) | 0.01, 0.1 ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% Full Scale |
Data Points | 500 |
Inputs | Conductivity, ATC |
Accuracy (Temperature) | ±0.3°C (±0.5°F) |
Calibration Points (Conductivity) | 84 μS, 1413 μS, 12.88 mS, 111.8 mS |
Stability | Indicator Icons |
Warranty | 3 Years |
Resolution (Conductivity) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
Range (Conductivity) | 0 μS to 500 mS |
AC Adapter | Universal Power Adapter |
Resolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
Calibration | Conductivity, TDS, Salinity, Temperature |
Calibration Points | 1 to 5 (Conductivity), 1 to 5 (TDS), 1 (Salinity), 1 (Temperature) |
Accuracy (TDS) | ±1% Full Scale |
IP Rating | IP54 |
Data Logging | Automatic with Auto-read and Timed Modes, Manual with Continuous Mode |
Model | AB330 |
Outputs | Port for Computer or Printer |
Frequency | 50/60 Hz |
Backlight Option | Yes |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature Range (Metric) | -5°C to +105°C |
Oakton™ Waterproof Big Display pHTestr™ 30
Versatile, compact design works in a field or laboratory setting.

Diameter (English) | 1.5 in. |
---|---|
Warranty | 1 Year |
Length (Metric) | 16.5 cm |
Temperature (English) Operating | 32.0°F to 122.0°F |
Detection Range | -1 to 15 pH |
Resolution (pH) | 0.01 |
Measurement Modes | pH |
Range (pH) | -1 to 15 |
Calibration | Automatic |
For Use With (Application) | Hold function, auto-off, error messages, waterproof, dustproof and floatable |
Accuracy (pH) | ±0.01 |
Calibration Points | 1 to 3 |
Accuracy | ±0.1 pH |
Display Type | LCD |
IP Rating | IP66/67 |
Diameter (Metric) | 3.8 cm |
Backlight Option | None |
Certifications/Compliance | NIST |
Resolution (Temperature) | 0.1°C |
Temperature (Metric) Operating | 0°C to 50°C |
Accuracy (Temperature) | ±1°C |
Resolution | 0.1pH |
Oakton™ General-Purpose pH Probe, Refillable, Double junction, Glass, 3 ft Cable, BNC
Replacement Electrodes

Fisherbrand™ Replacement Probes for Traceable™ Conductivity and TDS Meters
For use with Traceable Conductivity and TDS Meters.
Type | Conductivity Probe |
---|---|
Material | Glass |
Fisherbrand™ accumet™ Liquid-Filled pH/ATC Epoxy Body Combination Electrodes - Mercury-Free
Single-junction models with Ag/AgCl reference element
Fisherbrand™ accumet™ Gel-Filled Polymer Body pH/ATC Double-Junction Combination Electrodes: Mercury-Free
Combine the convenience of a combination electrode with built-in ATC probe
Type | pH/ATC Combination Electrode |
---|---|
Length (Metric) Cable | 0.10 m |
Length (Metric) | 106 mm |
Temperature (English) Operating | 23°F to 176°F |
pH Range | 0 to 14 |
Color | Purple |
Length (English) | 4 in. |
Length (English) Cable | 30 in. |
Filling Solution Type | Gel |
Material | Epoxy |
Junction | Double |
Temperature (Metric) Operating | -5°C to +80°C |
Internal Reference | Ag/AgCl |
Fisherbrand™ accumet™ Glass Body Standard Size Combination Electrodes - Mercury-Free
For routine pH and titration measurements with small samples and small vessels, where separate half-cell electrodes may be impractical
Type | Combination pH Electrode |
---|---|
Temperature (Metric) Range | -5°C to +100°C |
Length (Metric) | 101.6 mm |
pH Range | 0 to 14 |
Length (English) | 4 in. |
Material | Glass |
Closure Type | Twist Open/Twist Close |
Internal Reference | Ag/AgCl |